JACOB pipeworks has been regularly tested for use in potentially explosive environments since 1980. The products are examined for their shock explosion resistance by means of a gas explosion, dust explosion or stress analysis. The results are documented in test reports from our external partners such as DEKRA GmbH and Inburex Consulting GmbH.
Pipes and press-formed components up to DN 315 with a wall thickness of 1 to 1.5 mm with (Quick Connect) pull-ring connections made of mild steel and stainless steel were tested.
You can find more information in our catalogue or in the technical information.
Pipes and press-formed components up to DN 315 with a wall thickness of 1.5 to 2 mm with (Quick Connect) pull-ring connections made of mild steel and stainless steel were tested.
You can find more information in our catalogue or in the technical information.
Pipes and press-formed components up to DN 315 with a wall thickness of 2 to 3 mm with loose flange connections made of mild steel and stainless steel were tested.
You can find more information in our catalogue or in the technical information.
Pipes and press-formed components up to DN 300 with a wall thickness of 2 mm with angle flange connections made of mild steel were tested.
You can find more information in our catalogue or in the technical information.
In order to maintain the shock explosion proof, the pipe parts in operation must be checked regularly for wear and corrosion. Deteriorated components must be replaced.